Component Manual for the Neutron Ray-Tracing Package McStas, version 3.8.6

12.38  The Union_abs_logger_1D_space_tof McStas Component

Logger of absorption along 1D space and 1D time of flight

Identification

Description

Part of the Union components, a set of components that work together and thus separates geometry and physics within McStas. The use of this component requires other components to be used.

1) One specifies a number of processes using process components 2) These are gathered into material definitions using Union_make_material 3) Geometries are placed using Union_box/cylinder/sphere, assigned a material 4) Logger and conditional components can be placed which will record what happens 5) A Union_master component placed after all of the above

Only in step 5 will any simulation happen, and per default all geometries defined before this master, but after the previous will be simulated here.

There is a dedicated manual available for the Union_components

This component is an absorption logger, and thus placed in point 4) above.

A absorption logger will log something for each absorption event happening in the geometry or geometries on which it is attached. These are specified in the target_geometry string. By leaving it blank, all geometries are logged, even the ones not defined at this point in the instrument file. Multiple geometries are specified as a comma separated list.

This absorption logger records the absorbed intensity as a function of the y position and time of flight. One common use could be to attach this absorption logger to a cylindrical helium-3 volume, creating a model of the detector volume. In such a detector, only the y position of the event is known, and as such creates a similar dataset.

This absorption logger needs to be placed in space, the position is recorded in the coordinate system of the logger component. Note the detection is along the y axis of the component, so it is natural to place it relative to a cylinder.

It is possible to attach one or more conditional components to this absorption logger. Such a conditional component would impose a condition on the state of the neutron after the Union_master component that executes the simulation, and the absorption logger will only record the event if this condition is true.

To use the logger_conditional_extend function, set it to some integer value n and make and extend section to the master component that runs the geometry. In this extend function, logger_conditional_extend[n] is 1 if the conditional stack evaluated to true, 0 if not. This way one can check what rays is logged using regular McStas monitors. Only works if a conditional is applied to this logger.

Input parameters

Parameters in boldface are required; the others are optional.

Name

Unit

Description

Default

target_geometry

string

Comma separated list of geometry names that will be logged, leave empty for all volumes (even not defined yet)

"NULL"

yheight

m

height of absorption logger

n

1

number of bins for spatial axis

0.2

time_min

s

Minimum time recorded

0

time_max

s

Maximum time recorded

1

time_bins

1

number of time bins

100

filename

string

Filename of produced data file

"NULL"

order_total

1

Only log rays that have scattered n times, -1 for all orders

-1

order_volume

1

Only log rays that have scattered n times in the same geometry, -1 for all orders

-1

logger_conditional_extend_index

1

If a conditional is used with this logger, the result of each conditional calculation can be made available in extend as a array called "logger_conditional_extend", and one would then access logger_conditional_extend[n] if logger_conditional_extend_index is set to n

-1

init

string

name of Union_init component (typically "init", default)

"init"

nowritefile

1

If set, logger will skip writing to disk

0

Links