A radial divergence sensitive monitor with wavelength restrictions.
Author: Kaspar Hewitt Klenø, modified from Hdiv_monitor
Origin: NBI
Date: Jan 2011
A radial divergence sensitive monitor with wavelength restrictions. The counts are distributed in n pixels.
Example:
Parameters in boldface are required; the others are optional.
|
Name |
Unit |
Description |
Default |
|
|
|||
|
ndiv |
1 |
Number of pixel rows |
20 |
|
restore_neutron |
1 |
If set, the monitor does not influence the neutron state |
0 |
|
filename |
str |
Name of file in which to store the detector image |
|
|
xmin |
m |
Lower x bound of detector opening |
0 |
|
xmax |
m |
Upper x bound of detector opening |
0 |
|
ymin |
m |
Lower y bound of detector opening |
0 |
|
ymax |
m |
Upper y bound of detector opening |
0 |
|
xwidth |
m |
Width/diameter of detector (x). Overrides xmin,xmax. |
0 |
|
yheight |
m |
Height of detector (y). Overrides ymin,ymax. |
0 |
|
maxdiv_r |
deg |
Maximal radial divergence detected |
2 |
|
Lmin |
Å |
Minimum wavelength detected |
|
|
Lmax |
Å |
Maximum wavelength detected |
|
|
|
|||
|
|
|||
|
|
|||
Component source code found in file Radial_div.comp.