Component Manual for the Neutron Ray-Tracing Package McStas, version 3.8.6

15.13  The ESS_moderator_short McStas Component

A parametrised pulsed source for modelling ESS short pulses.

Identification

Description

Produces a time-of-flight spectrum, from the ESS parameters Chooses evenly in lambda, exponentially decaying in time . Adapted from Moderator by: KN, M.Hagen, August 1998

Units of flux: n/cm^2/s/Å/ster (McStas units are in general neutrons/second)

Example general parameters (general): size=0.12 Lmin=0.1 Lmax=10 dist=2 focus_xw=0.06 yh=0.12 nu=50 branchframe=0.5

Example moderator specific parameters (From F. Mezei, "ESS reference moderator characteristics for ...", 4/12/00: Defining the normalised Maxwelian M(lam,T) = 2 a^2 lam^-5 exp(-a/lam^2); a=949/T; lam in Å; T in K, and the normalised pulse shape function F(t,tau,n) = ( exp(-t/tau) - exp(-nt/tau) ) n/(n-1)/tau, the flux distribution is given as Phi(t,lam) = I0 M(lam,T) F(t,tau,n) + I2/(1+exp(chi2 lam-2.2))/lam*F(t,tau2*lam,n2) )

a1: Ambient H20, short pulse, decoupled poisoned

T=325 tau=22e-6 tau1=0 tau2=7e-6 n=5 n2=5 chi2=2.5
I0=9e10 I2=4.6e10    branch1=0 branch2=0.5

a2: Ambient H20, short pulse, decoupled un-poisoned

T=325 tau=35e-6 tau1=0 tau2=12e-6 n=5 n2=5 chi2=2.5
I0=1.8e11 I2=9.2e10    branch1=0 branch2=0.5

a3: Ambient H20, short pulse, coupled

T=325 tau=80e-6 tau1=400e-6 tau2=12e-6 n=20 n2=5 chi2=2.5
I0=4.5e11 I2=9.2e10    branch1=0.5 branch2=0.5

b1: Liquid H2, short pulse, decoupled poisoned

T=50 tau=49e-6 tau1=0 tau2=7e-6 n=5 n2=5 chi2=0.9
I0=2.7e10 I2=4.6e10    branch1=0 branch2=0.5

b2: Liquid H2, short pulse, decoupled un-poisoned

T=50 tau=78e-6 tau1=0 tau2=12e-6 n=5 n2=5 chi2=0.9
I0=5.4e10 I2=9.2e10    branch1=0 branch2=0.5

b3: Liquid H2, short pulse, coupled

T=50 tau=287e-6 tau1=0 tau2=12e-6 n=20 n2=5 chi2=0.9
I0=2.3e11 I2=9.2e10    branch1=0 branch2=0.5

Input parameters

Parameters in boldface are required; the others are optional.

Name

Unit

Description

Default

size

m

Edge of cube shaped source

Lmin

Å

Lower edge of wavelength distribution

Lmax

Å

Upper edge of wavelength distribution

dist

m

Distance from source to focusing rectangle; at (0,0,dist)

focus_xw

m

Width of focusing rectangle

focus_yh

m

Height of focusing rectangle

nu

Hz

Frequency of pulses

50

T

K

Temperature of source

325

tau

s

long time decay constant for pulse, 1a

22e-6

tau1

s

long time decay constant for pulse, 1b (only for coupled water, else 0)

0

tau2

s/Å

long time decay constant for pulse, 2

7e-6

n

1

pulse shape parameter 1

5

n2

1

pulse shape parameter 2

5

chi2

1/Å

lambda-distribution parameter in pulse 2

2.5

I0

flux

integrated flux 1 (in flux units, see above) (default 9e10)

9e10

I2

flux*Å

integrated flux 2 (default 4.6e10)

4.6e10

branch1

1

limit for switching between distribution 1 and 2. (has effect only for coupled water, tau1>0)

0

branch2

1

limit for switching between distribution 1 and 2. (default value 0.5)

0.5

branchframe

1

limit for switching between 1st and 2nd pulse (if only one pulse wanted: 1)

0

target_index

1

relative index of component to focus at, e.g. next is +1 this is used to compute ’dist’ automatically.

1

Links